Communications...an extensive range of options!
 | Digital |
 | Cellular |
 | Long Range Radio |
 | Event Initiated Paging |
|
|
|
|
|
| PC4010 /
PC4020... Expandability that's built-in
for installation flexibility and economy!
Start with 8 or 16 zones and expand to 64 or 128 by
choosing the best combination of technologies to suit the job at hand:
COMBUS expansion
add zone input modules right
up to 64 or 128 zones, as well as a host of other output modules, relay modules, etc
all on a 4-conductor non-shielded station wire bus.
ADDRESSABLE LOOP expansion
built right onto
the main panel, addressable loops make zone expansion simple using DSC addressable
devices. Add 56 or 112 addressable devices for panel expansion to full capacity of 64 or
128 zones.
WIRELESS expansion
makes filling the gap where
hardwiring is difficult, disruptive, or cost prohibitive as easy as connecting a MAXSYS 64
zone wireless receiver to the COMBUS and choosing from an array of DSC wireless components
including PIRs, door contact modules, smoke detectors, emergency pendants, and for
flexibility of control 4 button key fobs and handheld keypads. |
|
|
|
|
|
LOADED WITH
FEATURES
"RIGHT OUT OF THE BOX" |
| · |
4 or 8 system
partitions |
| · |
1,000 user codes |
| · |
3,000 event
buffer |
| · |
30 programmable
zone types |
| · |
59 programmable
output options |
| · |
local and remote
upload/download |
| · |
99 date
schedules |
| · |
50 arm/ disarm
schedules |
| · |
99 open/ close
suppression schedules |
| · |
two-year holiday
scheduling |
| · |
automatic
daylight savings adjustment |
| · |
add up to 16 LCD
keypads |
| · |
add up to 64
programmable relays |
| · |
add up to 144
low power outputs |
| · |
add
point/graphic annunciation |
| · |
UL & ULC
listed for :
· residential
· commercial applications |
| · |
And much
more
|
|
|
|
 |
| |
 |
| |
| |
COMBUS...
input zone modules, low power outputs, programmable relays, access control modules, remote
annunciators all connected to the main panel via a 4-wire, #22 AWG non-shielded cable.
With input/output modules located remotely - on up to 4 runs of 1,000 feet (305m) each -
home-run wiring is eliminated and the installation is simplified for the installer. |
|
| |
|
 |
|
| Plain Language Keypads... What could be more user-friendly!
Take the mystery out of security system operation with up to 16 easy to read 32
character LCD keypads, each with five programmable function keys to make regular
operations a snap. Connected to the COMBUS, keypads can be assigned for global or
partition usage. |
|
|
| |
Adressable Loops... Make expansion easy and economical!
Right out of the box ready to go no modules to add expand the
system to full zone capacity with 2-wire addressable loops built right onto the main
panel. Addressable loops reduce costs through minimum module and wire usage
for
maximum installation efficiency and economy! |
|
| |
Addressable Devices...
| AMA-100 |
- |
Glassbreak detector |
| AMB-300 |
- |
PIR motion detector |
| AMB-500 |
- |
Ceiling mount PIR motion detector |
| AMB-600 |
- |
Pet-immune PIR motion detector |
| AMP-700 |
- |
Door/ window contact |
| AMP-701 |
- |
Point module 3 NC inputs |
| AMS-220 |
- |
Photoelectric smoke detector |
| AMS-220T |
- |
Photoelectric smoke detector
w/ 135° heat detector |
|
 |
|
|
|
|
|
|
|
 |
|
| Remote Zone Expanders... Flexibility at hand!
Need to add 8 zones here, 16 zones there? Go right ahead with MAXSYS remote zone
expanders. Simply connect them to the COMBUS for flexible, efficient, distributed zone
expansion. |
|
 |
|
| Wireless Expansion... Convenience and protection!
For those hard to wire locations, add up to 64 wireless zones; and for personal
protection and operating convenience add up to 64 emergency pendants, 16 key fobs, and 4
handheld keypads using DSC's proven 900MHz true spread spectrum wireless technology. |
|
|
| |
Remote Annunciation... Information in plain sight!
DSC's unique point or graphical annunciators can display up to 144 zone, partition, and
system events, providing critical information for operating and emergency service
personnel.
Easy to install, with just 4 wires to the COMBUS the PC4632/PC4664, 32/64 point
annunciators provide direct system status and can be flush-mounted for an attractive
installation. |
|
| |
| |
 |
|
|
|
|
|
|

|
|
|
|
PC4701 Fire Module...
With the 2 supervised communicator outputs critical to all commercial fire alarm
systems, the PC4701 included with the main control panel also provides smoke detector and
water flow zones, as well as fire alarm-actuated and fire trouble-actuated output relays. |
|
PC4204CF
Quad Relay & Power Supply Panel... Packaged in an enclosure with
transformer and battery charger to meet UL864 requirements, the PC4204CF is the fire
version of the PC4204 for security systems. Each PC4204(CF) provides added power for the
COMBUS plus 4 high current relays. With up to 16 PC4204(CF) modules, the system can
include a total of 64 fully programmable relays. |
|
|
| |
| |
 |
Fire Zone
Annunciation... Fire specific information
at a glance!
Especially designed for fire systems, the PC4612 complements the use of standard
PC4632/ PC4664 annunciators, which may be used on the same fire system, by adding specific
annunciation for fire alarm zones, fire supervisory zones, and fire troubles. |
|
| |
|
|
|
|
|
| PC4010CF
/ PC4020CF... with UL864
Commercial Fire listings
plus
all the features of MAXSYS security systems!
Take a MAXSYS security system with fire savvy software and
specially engineered fire application hardware, and not only do you have a great security
system, you also have a powerful fire alarm system. |
|
PC4702BP Dual Bell
Output Panel
Complete with integral transformer and battery charger, the
PC4702BP connects to the COMBUS wherever required to provide audible & visual fire
alarm notification zones.
With up to 4 panels per system, 8 zones total, and each zone providing 1.8 Amps at 24
VDC, MAXSYS solves the power issues for fire alarm strobes and horns. |
|
Addressable
Smoke detectors...
Use addressable loops to add up to 56 DSC UL/ ULC listed addressable smoke detectors on
PC4010CF systems and 112 on PC4020CF systems to meet the needs of large applications
efficiently and economically. |
|
Universal Remote Zone expansion...
Use any mix of listed security and fire alarm detectors on the same zone expanders as
the MAXSYS security system. Commercial Fire zones can be standard fire, water flow,
auto-verify fire, and fire supervisory. |
|
|
|
| |
| |
Special
Software Features for Fire
Alarm
Auto-Scroll
displays fire alarms and selected fire troubles at two second
intervals on all system keypads.
Fire Drill
user-initiated for easy evacuation drills.
Fire Inspector's Test
simplifies system verification testing.
Auto-Verify
programmable by zone for 2-wire, 4-wire and addressable
smoke detector zones.
Waterflow Delay
programmable timer for waterflow zones.
Fire Silence Inhibit
prevent manual signal silence for a
programmable time period.
Synchronized Temporal Pattern
automatic synchronized audible alarm
notification for zones programmed with the temporal pattern. |
|
| |
|
|
|
|
|
|

|
| |
 |
| |
| |
 |
|
|
| PC4820 Dual Reader Access
Control... integrates Access Control with
MAXSYS fire and security systems for single system responsibility! |
|
Supporting a Complete Line of Readers...
| · |
Polaris Mag-stripe |
| · |
ShadowProx proximity |
| · |
HID proximity |
| · |
26 Bit standard Wiegand |

T.Rex Exit Detectors
Hands-free, automatic, no buttons to push !
Designed specifically for access control applications, the T.Rex provides fast,
accurate detection and door unlocking. |
|
| Features |
| · |
up to 16 dual
reader panels for 32 readers per system |
| · |
full standalone
operation
complete card database & all programming is maintained in the PC4820's
non-volatile memory |
| · |
arm/ disarm
partitions & postpone autoarm by access card or access card and code
from outside
the protected space |
| · |
64 access levels |
| · |
99 seven-day
schedules |
| · |
4 two year
holiday groups - 730 holidays |
| · |
individual door
unlock schedules |
| · |
automatic
switching between daylight savings & standard time |
| · |
program via
keypad, or via computer with DLS-2 upload/download software |
|
|
|
|
|
 |
|
Escort4580 Voice Assisted Security and Automation
Control Module
The Escort4580 operates in conjunction with any touch-tone
telephone to provide an easy to understand plain language interface for MAXSYS Security
Systems. Escort allows the telephone to be used as a keypad while providing the user with
operational and programming voice prompts as well as plain language system status reports.
In addition, Escort acts as an interface for up to thirty two X-10 automation control
devices complete with voice assisted operation and programming. |
|
PC4400 Printer or
DVACS Output module
Use as a true RS-232 serial interface to a serial printer
and receive comprehensive management information reports from MAXSYS' 3,000 event buffer
or, in Canada, optionally use the PC4400 as a DVACS interface to take advantage of
available high security DVACS communications networks. |

|