Since 1975 Moore Associates Security Systems

Home Up Search Contact UsMaxSys

 
MAXSYS Security
 
         MAXSYS Security
         Integrated Systems Technology
Communications...an extensive range of options!
bulletDigital
bulletCellular
bulletLong Range Radio
bulletEvent Initiated Paging
PC4010   /   PC4020...

Expandability that's built-in for installation flexibility and economy!

Start with 8 or 16 zones and expand to 64 or 128 by choosing the best combination of technologies to suit the job at hand:

COMBUS expansion… add zone input modules right up to 64 or 128 zones, as well as a host of other output modules, relay modules, etc… all on a 4-conductor non-shielded station wire bus.

ADDRESSABLE LOOP expansion… built right onto the main panel, addressable loops make zone expansion simple using DSC addressable devices. Add 56 or 112 addressable devices for panel expansion to full capacity of 64 or 128 zones.

WIRELESS expansion… makes filling the gap where hardwiring is difficult, disruptive, or cost prohibitive as easy as connecting a MAXSYS 64 zone wireless receiver to the COMBUS and choosing from an array of DSC wireless components including PIRs, door contact modules, smoke detectors, emergency pendants, and for flexibility of control – 4 button key fobs and handheld keypads.

Complete with SIA false alarm reduction
Residential Commercial Industrial Institutional
LOADED WITH FEATURES
"RIGHT OUT OF THE BOX"
· 4 or 8 system partitions
· 1,000 user codes
· 3,000 event buffer
· 30 programmable zone types
· 59 programmable output options
· local and remote upload/download
· 99 date schedules
· 50 arm/ disarm schedules
· 99 open/ close suppression schedules
· two-year holiday scheduling
· automatic daylight savings adjustment
· add up to 16 LCD keypads
· add up to 64 programmable relays
· add up to 144 low power outputs
· add point/graphic annunciation
· UL & ULC listed for :
·  residential
·  commercial applications
· And much more…
Residential Commercial Industrial Institutional
 
MAXSYS Security
 
  COMBUS... input zone modules, low power outputs, programmable relays, access control modules, remote annunciators all connected to the main panel via a 4-wire, #22 AWG non-shielded cable. With input/output modules located remotely - on up to 4 runs of 1,000 feet (305m) each - home-run wiring is eliminated and the installation is simplified for the installer.  
 
Plain Language Keypads
Plain Language Keypads...

What could be more user-friendly!

Take the mystery out of security system operation with up to 16 easy to read 32 character LCD keypads, each with five programmable function keys to make regular operations a snap. Connected to the COMBUS, keypads can be assigned for global or partition usage.

 
Adressable Loops...

Make expansion easy and economical!

Right out of the box – ready to go – no modules to add – expand the system to full zone capacity with 2-wire addressable loops built right onto the main panel. Addressable loops reduce costs through minimum module and wire usage… for maximum installation efficiency and economy!

 
 
Addressable Devices...
AMA-100 - Glassbreak detector
AMB-300 - PIR motion detector
AMB-500 - Ceiling mount PIR motion detector
AMB-600 - Pet-immune PIR motion detector
AMP-700 - Door/ window contact
AMP-701 - Point module – 3 NC inputs
AMS-220 - Photoelectric smoke detector
AMS-220T - Photoelectric smoke detector
w/ 135° heat detector
 
Remote Zone Expanders
Remote Zone Expanders...

Flexibility at hand!

Need to add 8 zones here, 16 zones there? Go right ahead with MAXSYS remote zone expanders. Simply connect them to the COMBUS for flexible, efficient, distributed zone expansion.

Wireless Expansion
Wireless Expansion...

Convenience and protection!

For those hard to wire locations, add up to 64 wireless zones; and for personal protection and operating convenience add up to 64 emergency pendants, 16 key fobs, and 4 handheld keypads using DSC's proven 900MHz true spread spectrum wireless technology.

 
Remote Annunciation...

Information in plain sight!

DSC's unique point or graphical annunciators can display up to 144 zone, partition, and system events, providing critical information for operating and emergency service personnel.

Easy to install, with just 4 wires to the COMBUS the PC4632/PC4664, 32/64 point annunciators provide direct system status and can be flush-mounted for an attractive installation.

 
 
  Remote Annunciation   Remote Annunciation  

 
MAXSYS Security
 
         MAXSYS Access Control
PC4820 Dual Reader Access
Control
T.Rex Exit Detectors
PC4820 Dual Reader Access Control... integrates Access Control with MAXSYS fire and security systems for single system responsibility!

Supporting a Complete Line of Readers...
· Polaris Mag-stripe
· ShadowProx proximity
· HID proximity
· 26 Bit standard Wiegand

T.Rex Exite Detector
T.Rex Exit Detectors…

Hands-free, automatic, no buttons to push !

Designed specifically for access control applications, the T.Rex provides fast, accurate detection and door unlocking.

Features
· up to 16 dual reader panels for 32 readers per system
· full standalone operation… complete card database & all programming is maintained in the PC4820's non-volatile memory
· arm/ disarm partitions & postpone autoarm by access card or access card and code…from outside the protected space
· 64 access levels
· 99 seven-day schedules
· 4 two year holiday groups - 730 holidays
· individual door unlock schedules
· automatic switching between daylight savings & standard time
· program via keypad, or via computer with DLS-2 upload/download software
MAXSYS Security

Escort4580 Voice Assisted Security and Automation Control Module

Escort4580 Voice Assisted Security and Automation Control Module…

The Escort4580 operates in conjunction with any touch-tone telephone to provide an easy to understand plain language interface for MAXSYS Security Systems. Escort allows the telephone to be used as a keypad while providing the user with operational and programming voice prompts as well as plain language system status reports. In addition, Escort acts as an interface for up to thirty two X-10 automation control devices complete with voice assisted operation and programming.

PC4400 Printer or DVACS Output module

PC4400 Printer or
DVACS Output module…

Use as a true RS-232 serial interface to a serial printer and receive comprehensive management information reports from MAXSYS' 3,000 event buffer or, in Canada, optionally use the PC4400 as a DVACS interface to take advantage of available high security DVACS communications networks.

 

Home ] Up ]

Send mail to gmoorejr@dialonemoore.com with questions or comments about this web site.
Copyright © 2001 DIAL ONE Moore Associates Security Systems